Sérülékenységek

CVE-2025-21590

Juniper Networks Junos OS

Adatlap

Eszköztípus
IT
Publikálva
Frissítve
Súlyosság
Közepes
Prioritás
Riasztás
CWE
CWE-653

CVSS-pontszámok

Verzió Pontszám Súlyosság Vektor
3.1 4,4 Közepes CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N
4.0 6,7 Közepes CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N

Helyi hozzáférés szükséges · Alacsony komplexitás · Magas jogosultság szükséges · Nem szükséges felhasználói interakció

Eredeti leírás

An Improper Isolation or Compartmentalization vulnerability in the kernel of Juniper Networks Junos OS allows a local attacker with high privileges to compromise the integrity of the device.

A local attacker with access to the shell is able to inject arbitrary code which can compromise an affected device.
This issue is not exploitable from the Junos CLI.
This issue affects Junos OS: 

* All versions before 21.2R3-S9,
* 21.4 versions before 21.4R3-S10, 
* 22.2 versions before 22.2R3-S6, 
* 22.4 versions before 22.4R3-S6, 
* 23.2 versions before 23.2R2-S3, 
* 23.4 versions before 23.4R2-S4,
* 24.2 versions before 24.2R1-S2, 24.2R2.

Érintett termékek

  • Junos OS Juniper Networks Verziók: 0 – < 21.2R3-S9; 21.4 – < 21.4R3-S10; 22.2 – < 22.2R3-S6; 22.4 – < 22.4R3-S6; 23.2 – < 23.2R2-S3; 23.4 – < 23.4R2-S4; 24.2 – < 24.2R1-S2, 24.2R2

Prioritás

Szint
Riasztás
Teendő
Azonnali intézkedés javasolt: a szoftvert 24 órán belül frissítse. Ha a frissítés nem telepíthető azonnal, alkalmazza a gyártó által javasolt kerülő megoldást, és a javításig fokozottan figyelje a sérülékenység kihasználására irányuló kísérleteket.

Kihasználási státusz

EPSS
1,75%
Kihasználtság
Aktív
Kihasználás óta
Automatizálhatóság
Nem
Technikai hatás
Teljes
Exploitok

At least one instance of malicious exploitation has been reported to the Juniper SIRT. Customers are encouraged to upgrade to a fixed release as soon as it's available and in the meantime take steps to mitigate this vulnerability.

Javítás

Javított verzió
21.2R3-S9, 21.4R3-S10, 22.2R3-S6, 22.4R3-S6, 23.2R2-S3, 23.4R2-S4, 24.2R1-S2, 24.2R2
Gyártói hivatkozás
Van patch vagy gyártói közlemény a hivatkozások között

Megoldás (CNA)

The following software releases have been updated to resolve this specific issue: 21.2R3-S9, 21.4R3-S10, 22.2R3-S6, 22.4R3-S6, 23.2R2-S3, 23.4R2-S4, 24.2R1-S2, 24.2R2, 24.4R1, and all subsequent releases.

 

Please note that this issue is not fixed for all platforms in the releases specified in the solution section.

For the following products the fix is only available in these releases:

SRX300 Series   21.2R3-S9, 23.4R2-S5*, 24.4R1

SRX550HM    22.2R3-S7*

EX4300 Series     21.4R3-S11* (except EX4300-48MP which has fixes available as indicated in the solution)

EX4600               21.4R3-S11* (except EX4650 which has fixes available as indicated in the solution)

ACX1000, ACX1100, ACX2100, ACX2200, ACX4000,

ACX500              21.2R3-S9

MX104               21.2R3-S9

* Future Release

Kerülő megoldás (CNA)

It is strongly recommended to mitigate the risk of exploitation by restricting shell access to trusted users only.

Hivatkozások

Nemzeti Kiberbiztonsági Intézet
Adatvédelmi áttekintés

Weboldalunkon sütiket (cookie) használunk a látogatói forgalom elemzéséhez, az egyes felhasználói munkamenetek azonosításához, a tartalom és a hirdetések személyre szabásához, valamint a közösségi médiafunkciókhoz. Az "Összes elfogadása" gombra kattintva, Ön beleegyezik ezen cookie-k használatába, vagy az alábbi lehetőségek közül kiválaszthatja, mely sütiket engedélyezi. (Egyes sütik technikai okok miatt az első újratöltésig létrejöhetnek.)